site stats

Granular b type 2 opss

WebPage 11 Rev. Date: 11/2003 OPSS 1010 Table 3 Minimum Sampling and Testing Frequency for Control Chart Use Material Frequency for Type 1 Control Chart t Frequency for Type 2 Control Chart t Granular A, M, and S 2,500 5,000 Granular B and SSM 5,000 10,000 Granular O 2,000 4,000 Table 4 Sample Size Material Minimum Mass of … WebGranular B Type I. Product Details. Size: Particles range from dust size to less than 150mm. Description: Well-graded product meeting provincial specifications (OPSS …

Granular B Type 2 Limestone – GravelTop

Webthen opss 1010 granular 'b' type ii in the absence of specified backfill, or authority having jurisdication. backfill as per project specific design 1. granular material to be placed in trench in 150mm lifts (max.) and compacted to 100% standard proctor maximum dry density (spmdd). 11. 5. cover material to be as per opss 1010 granular 'a'. WebFor proper placement and compaction, the asphalt lift thickness should be at least 2.5 to 3.0 times the maximum particle diameter. HL 3 aggregates have a nominal maximum size of 13.2 mm, requiring a minimum mat thickness of at least 35 mm. HL 4 is a slightly coarser mix with aggregates of a nominal maximum size of 16 mm, and hence requiring a ... laughin cats https://bloomspa.net

OPSS - MUNI 1010 Nov 13 PDF Construction Aggregate - Scribd

WebMar 2, 2024 · Aggregate Recycling Ontario has also requested that the OPS revise OPSS 1010 (granular base and sub-base aggregates) to allow the use of recycled aggregate in … WebOPSS 501.05.01 Granular Material . ... The type of compaction equipment used shall be suited to the material to be compacted, degree of compaction required, and space … WebWhen Granular B is used for granular backfill for pipe subdrains, 100% of the material shall pass the 37.5 mm sieve. When RAP is blended with Granular B Type I or Type III, … laugh-in cast pictures

PART 1 – GENERAL 1.01 DESCRIPTION 1.02 RELATED …

Category:OPSS 1010 Nov03 PDF Construction Aggregate Quality …

Tags:Granular b type 2 opss

Granular b type 2 opss

Solved Problem 2 A contractor submitted two samples of - Chegg

WebGranular B Type II. Product Details. Size: Particles range from dust size to less than 106mm. Description: Well-graded product meeting provincial specifications (OPSS 1010). 100% crushed quarried rock. Use. … WebGranular B Type 2 Limestone is a 2” minus material, meaning it contains stone ranging from 2” down to fines. Generally Granular B Type 2 is a base material, used in heavy traffic areas for high stability applications. With excellent compaction this material will resist erosion and makes for a great driveway base, road base, or parking lot ...

Granular b type 2 opss

Did you know?

Web2.9 OPSS 1010, Ontario Provincial Standard Specification for Granular A, Granular B, Granular M, and Select Subgrade Material (SSM) 3. APPARATUS 3.1 BALANCE: 3.1.1 Fine Aggregate: A balance or scale readable to 0.1 g and accurate to within 0.1% of the test ... For Granular B Type I, Granular B Type II and SSM, the minimum test sample mass WebGranular B Type 2 Limestone is a 2” minus material, meaning it contains stone ranging from 2” down to fines. Generally Granular B Type 2 is a base material, used in heavy …

WebMar 1, 2024 · Aggregate Recycling Ontario has also requested that the OPS revise OPSS 1010 (granular base and sub-base aggregates) to allow the use of recycled aggregate in granular B, type II products. The current 2013 specification, however, is not up for review until 2024 (five-year cycle). WebTable 2 of OPSS.MUNI 1010 is amended by the addition of column . 50 mm Crushed Aggregate . as follows: Table 2: Gradation requirements – percent passing . M num b er …

WebOPSS Granular A : Passes 1" • • • • OPSS Granular B Type I (Pit Run) 0 - 1/2" • • • • Unprocessed Fines: Unscreened Sand Fill • • • Oversized/Landscaping: Armour Stone - Random • Armour Stone - Random Size/Shape: 1 - 2 tonne • Armour Stone - Random Size/Shape: 2 - 4 tonne • Armour Stone - Landscape Stackable: 10 ... WebSample 2 is intended for use as Granular B Type III, per the OPSS 1010 specifications. The following table has the results of the grain size analyses: a) Create a table for sample 1 …

Webopss 1006 november 2006 material specification for aggregates - surface treatment table of contents 1006.01 scope 1006.02 references 1006.03 definitions 1006.04 submission and design requirements 1006.05 materials 1006.06 equipment - not used 1006.07 production 1006.08 quality assurance 1006.09 owner purchase of material - not used …

WebGranular B Type II is 100% crushed stone and may only be obtained from quarried rock. 100% passes through the 150 mm (6 inch) sieve and may include any range of sizes between 6" and under. Used as a base … just dial history facts point 7Weba) Granular A. b) Granular B, Type I, II, or III, with 100% passing the 26.5 mm sieve. c) Unshrinkable fill. 401.05.02 Bedding Material . Bedding material shall be one of the following, as specified in the Contract Documents: a) Granular A. b) Granular B, Type I, II, or III, with 100% passing the 26.5 mm sieve. c) Unshrinkable fill. just dial history facts point 23WebType I-b: Emulsified asphalt primer according to OPSS 1103. b) Type II: Solvent-free emulsified asphalt according to OPSS 1103. c) Type III: Tall oil pitch (TOP) emulsion … just dial history facts point 21WebGranular b type 1 is perfect for gravel driveway restoration or installations and more. Categories. Aggregates. Related Products. Black Granite Screenings. A Gravel. B Gravel. 3/4"(19mm) Crusher Run Limestone. Limestone Screenings. Pit Run. 6" Minus Breaker Rock. 2" (50mm) Crusher Run Limestone ... laughin collegeWebMar 2, 2024 · Aggregate Recycling Ontario has also requested that the OPS revise OPSS 1010 (granular base and sub-base aggregates) to allow the use of recycled aggregate in granular B, type II products. The current 2013 specification, however, is not up for review until 2024 (five-year cycle). laugh in comedian johnsonWebMay 29, 2013 · OPSD 802.031 Rigid Pipe - Type 3 Earth Excavation, Class B Utilize the granular bedding and cover depths as specified in the applicable OPSD standards listed above. OPSS Granular A should be utilized for pipe embedment and pipe cover material for new piping. OPSS Granular B Type 1 material with a maximum particle size of 50mm may just dial history facts point 25Web1103 for Type I and Type II sealers, and OPSS 2510 for Type III granular sealers, respectively. A lot of sealer shall be deemed to be acceptable, if all the test results and other requirements according to OPSS 1103 for Type I and Type II sealers, and OPSS 2510 for Type III granular sealers are respectively met. laugh in cast members that are still alive