WebbGrease interceptors consist of a tank filled with water, entry and exit tees, a baffle, and access points for maintenance. As wastewater flows from a sink drain, it enters the tank through the inflow tee. This slows the velocity of the wastewater and allows it to enter the tank below the surface. Webb16 aug. 2024 · Aug 16, 2024. The purpose of a grease interceptor is to catch and collect fats, oils, grease, and solids (FOGS) from commercial and restaurant kitchens. As waste …
How Grease Traps/Interceptors Work
Webb28 feb. 2024 · The retention capacity of grease interceptors (in pounds) must be at least twice the numerical value of flowrate through the unit (in gallons per minute). For example, you need at least 40 lb for 20 gpm. A final requirement is that water flowing through a grease interceptor must not have a temperature above 180°F. WebbThe Z1170 Grease Interceptor is an acid resistant coated interior and exterior fabricated steel grease interceptor, PDI Rated, with internal air relief by-pass. This interceptor also comes standard with bronze cleanout plug, removable pressure equalizing/flow diffusing inlet baffle, fixed bottom outlet baffle and visible double wall trap seal. ritchie blackmore personality
PP66-14B 1-1/2" x 8" Dishwasher Branch Tailpiece Slip Joint or …
WebbGasketed non-skid secured cover complete with center tie down assembly, with Z1108 flow control fitting. Regularly furnished with threaded (as standard) high inlet and outlet connection. Note: Location of outlet from bottom of interceptor cannot be changed. Features & Benefits * Above or below grade applications * Sizes 500-800 PDI certified. WebbGrease interceptor type not specified in this table. Size of device is listed as wetted holding volume (gallons). Kitchen Drainage Fixtures using 1½” drain pipe gallons 2” drain pipe gallons One pre-rinse sink and dishwasher 300 500 One 2- or 3-compartment pot sink 300 500 One 2- or 3-compartment pot sink (and) WebbStudy with Quizlet and memorize flashcards containing terms like Each plumbing fixture, except for those having integral traps, shall be _____. (A) separately trapped by an approved liquid seal trap (B) drained by means of an indirect waste line (C) connected directly to the building drain without a trap (D) illegal and should not be used, One trap may serve a set … ritchie blackmore pictures